46 THD analysis

GM tester modified today to add an option to disconnect the CCS bypass capacitor so can drive the valve with an external signal and measure THD from output in common-cathode mode. The input is calibrated to produce 10Vrms (22.22dBu) at the anode and then signal is fed into the PC through the Pete Millet’s interface:

GM/THD tester

Did some sample tests with a set of lovely globe CX301a achieving THDs from 0.27% to 0.35%.

When looking at a driver valve such as 46 (triode-strapped) got THD values of around 0.05-0.09% for good valves. When picked up the faulty one I had discovered yesterday with the curve tracer, the THD shown to be 0.20% and over 0.35% in the worst one.

Need to retake these measures as the soundcard interface got damaged and results are showing significant distortion

 

20120604-122936.jpg
46 THD analysis

The PC generates a low distortion sine wave which is fed into the valve grid through the input capacitor. This is the same setup used for the transconductance test. The CCS in the anode is unbypassed to ensure the anode signal is not shunted to ground. The output is then taken out through the output PIO capacitor and fed back into the PC input adapter (Pete Millett’s sound card interface). Audiotester is used then to measure THD at 1kHz.

20120604-122954.jpg