Curve tracer finalised

After a long process, here it is. The curve tracer is finalised. It includes the following features:

Valve curve tracer

img_2995

  • Sockets: 4 pin, 5 pin, 7 pin, octal, loctal, 9 and compactron (10 and 12 pins)
  • Anode sweep: 0-330V
  • Anode current: 100mA (max)
  • Grid step generator: 8 steps, 0 to -80V and 0 to -5V steps
  • Grid output for calibration
  • Oscilloscope: X (x10 attenuation) and Y
  • Y amplifier:
    • x1/x10 differential amplifier
    • 1Ω / 10Ω sense resistor
    • Polarity inversion optional
    • Image sync adjust (coarse and fine)

Valve transconductance tester & THD meter

  • Anode current CCS 0-100mA (0.1mA resolution)
  • Anode voltage 0-600V (1V resolution)
  • Grid bias: 0 to -80V (0.1V resolution)
  • Transconductance meter:
    • 0-2,000 μmho scale (1 μmho resolution)
    • 2,000 – 40,000 μmho scale (100 μmho resolution)
    • Input test signal: 100mVrms @1kHz
  •  THD meter:
    • Soundcard I/O BNC connectors
    • CCS load or external load

img_3000

 