For those who are keen on the 26 preamp in filament bias and OT, here is my latest incarnation of this great pre-amp.
Tag: 46
4-65a SE driver
46 DHT in triode mode as a driver
Continuing with the design of the 4-65A SE amplifier based on M. Koster design, I’m in the process of tweaking the 46 driver to optimise the operating point and provide maximum distortion to drive the demanding 4-65a. Here is the circuit I’m currently working on.
The current 46 driver will be biased at around 25-30mA using filament bias, so Vgk will be around -16 to -17.5V using a 10Ω filament bias resistor array. This will set the 46 at around 185-210V which will give sufficient headroom (i.e. need about 200Vpp max) to drive the 4-65a.
So today I look at varying slightly both anode currents and Vgk to see impact on THD.
So minimum THD is around -17V and Ia=30mA. So if setting the Rod Coleman filament regulator to ensure that Vgk=-17V and the anode gyrator to set anode voltage to ensure Ia is close to bias current would provide the minimum distortion (which is 0.04% in this example). Pa is close to 7W, but looking at the datasheet we can see that maximum Pa is 10W (as the latter 45 version).
So next I need to build a prototype of this driver with filament regulator and gyrator load.
THD benchmark
I’m still in the process of testing valves, here is how the ranking is coming up so far. This is a mix of driver and output valves. All tested at Vo=+22.22dBu:
Looking at the chart above a couple of interesting points to highlight:
- 4P1L is the most linear valve I’ve found so far.
- 6e5P and 6C45 are expected to be on the top five anyway.
- 12P17L despite of having similar characteristics as 4P1L is not that linear
- 6N6P and 6N6P-I disappointed me. I thought the would be more linear..
- 46 and 47 in triode mode are superb drivers
Have so many other ones to test, but limited time….
Expect this chart to be updated in the future, so stay tuned 🙂
CX301a DHT pre-amplifier
CX301a DHT preamp
Here is my latest incarnation of the DHT pre-amplifier:
Many claim that the 26 is the best sounding DHT valve for a pre-amp. I will agree to a certain extent, however I personally found the thoriated-tungsten filament sound a bit more rewarding to my ears. A more clear and defined treble in my opinion.
Since I plugged in my CX301a incarnation of my breadboarded preamp, I just left it there as I loved its sound. Certainly there are things to be improved to enhance the dampening of microphony, albeit I have to confess it hasn’t been a problem to me. Have heard some valves to howl, and this is not one of those. Clearly suspending the valve socket or adding the rubber dampers to the valve holding plate or socket will help massively.
Filament bias is a must in my DHT designs. Since discovered it, can’t avoid not removing most capacitors that I can from the signal path. In this case the filament resistor R9 will increase anode resistance by R9 times (μ+1). This will also impact the stage gain, but here all this is not a problem. You may find this is way too much gain in your system. Rod Coleman’s filament DC regulators are crucial to provide a hum-free stage. Attempting AC or other DC regulator is likely to bring frustration to your design. Believe me, I’ve been there before…
Now turning our attention to the anode load I will not open a debate here (or a can of worms!). You can make your choice of using a superior quality output transformer (and by superior means a lot of money!) or you can look at various options. A choke is a great idea, but special care needs to be taken to ensure choke is not picking up any hum from the remaining parts of the circuit – specially the supply transformers, etc. I have experimented for some time various types of CCS or gyrators as sandy loads for the valves with excellent results. If you are one of those that feels that sand is a sacrilege, then I suggest you stop reading this post now.
Gyrators are superb. They can simulate the AC response of an inductor of 300H (but without storing energy as a real inductor) or above very easily at 1/100 of its cost. You can easily adjust the valve operating point ensuring this is maintained despite the ageing impact of the valve or the eventual replacement of it. The anode voltage will be fixed by the gyrator, the current not. Cascoded MOSFET gyrators provide better supply ripple rejection and isolation. Using Q3 as a CCS instead of a high resistance potentiometer to set the anode voltage is better as it helps providing a better frequency response as impedance on this node is increased. A higher value of R10 will help reducing the size of the gyrator capacitor and the smaller the better it will sound in my experience.
M1 and M2 can be your depletion FET of choice. M1 should be a 250V rated one at least. Depending where you live, you will be inclined for using BSP129, LND150 or DN2540.
Previously I mentioned in some other posts that the mu-follower setup of the gyrator here provides a better output impedance and improves the performance of this valve significantly given its high anode resistance compared to other more suitable DHTs for this purpose such as 4P1L, 46 or 71a.
I’m not going to cover the HT supply here, but using a shunt regulator such as Salas, is one of the best choices here.
With Russian PIO capacitors you will get a fantastic result here, no need to start burning serious money on the capacitors until you are happy with the end to end build and you can then start looking at how to improve the sound of it by replacing some bits with better (or preferred) quality components
With an operating point of Ia=3mA you can get THD=0.08% at Vo=10Vpp. This will be subject of the quality of your CX301a. Some older globe 01a’s have a great sound, but they are not that linear. Hard to pick and chose your precious ladies here without testing them for linearity.
Valve THD analysis
Measuring triode linearity
Today decided to do a quick distortion test of on a sample of a variety of different valves. All either triodes or triode-strapped pentodes/tetrodes. As per my previous tests, distortion was measured at +22.22dBu (10 Vrms) at the output of the valve in common-cathode mode. Valves were loaded with the CCS I use in my curve tracer. The operating points were quickly optimised at hand, so I’m sure there may be some better operating points for some of the valves below which may improve their overall THD. If you have any suggestions, please let me know!
Need to retake these measures as the soundcard interface got damaged and results are showing significant distortion
Interesting to see in the chart above, that 6e5p and 6C45p are the best ones. This is in line with their reputation as drivers as they are capable of swinging many volts and producing very low distortion. In terms of harmonics I noticed that 6e5P provides a richer H3 and H5 as being a triode-strapped valve, whereas the 6c45p provide a dominant H2.
Also good to see that my favourite 46, 4P1L and 6CB5A (all triode-strapped) are very linear with anode currents of 40mA (with the exception of 46 as I measured THD on a previous operating point used for transconductance measurement). I should retake the 46 and drive it harder, I’m sure it will perform better at higher current.
Surprised with the results of the 6N6P-I. Was expecting this one a bit better, but perhaps it’s the pulse version distortion, so may need to get hold of an 6N6P and compare the results.
Update:
It looks like I blew up Pete Millett’s interface after measuring THD in float mode and exceeding the 10Vrms limit in this mode. Therefore measures such as 26, CX301a and others are not accurate. When testing 26 with my Ferrograph test set it came out to be 0.05%…
Stay tune until I repair the unit!
46 THD analysis
GM tester modified today to add an option to disconnect the CCS bypass capacitor so can drive the valve with an external signal and measure THD from output in common-cathode mode. The input is calibrated to produce 10Vrms (22.22dBu) at the anode and then signal is fed into the PC through the Pete Millet’s interface:
Did some sample tests with a set of lovely globe CX301a achieving THDs from 0.27% to 0.35%.
When looking at a driver valve such as 46 (triode-strapped) got THD values of around 0.05-0.09% for good valves. When picked up the faulty one I had discovered yesterday with the curve tracer, the THD shown to be 0.20% and over 0.35% in the worst one.
Need to retake these measures as the soundcard interface got damaged and results are showing significant distortion
The PC generates a low distortion sine wave which is fed into the valve grid through the input capacitor. This is the same setup used for the transconductance test. The CCS in the anode is unbypassed to ensure the anode signal is not shunted to ground. The output is then taken out through the output PIO capacitor and fed back into the PC input adapter (Pete Millett’s sound card interface). Audiotester is used then to measure THD at 1kHz.
Finishing the curve tracer
Today I did a bit of extra work on the curve tracer with a view of finishing it. It has been a long and painful journey, but I’m reaching the end of it.
The transconductance tester is working perfect. I need to use the following ranges in my true RMS AC voltmeter:
- 0-2,000 μmho: 100mVrms scale
- 2,000μmho-50,0000μmho: 1Vrms scale
It’s probably the DC bias which affects the low scale. As an example when testing a 46 in triode mode (see datasheet for details), I tried the following operating point: Vg=-33V, Ia=22mA and the measure should be around 2.35 mVrms over 220mVdc. But in my bench voltmeter, above 17mA in the 46 doesn’t like it and cannot measure it, so need to change scale. I tested low transconductance valves in the lower AC scale such as CX301a, 26, 4P1L, 71a and then using the high AC scale, used 6e5P, 6C45, 6N6P amongst others.
The tracer now has a common-mode mains filter. This was required as at certain times during the day, specially in the evenings when the mains is really noise or my wife is using the microwave oven!, when tracing curves with the 1Ω sensing resistor and low anode currents (e.g. CX301a) then the noise level was sufficient to impact and distort the traced image. With the common-mode mains filter it works brilliantly.
Now need to place bottom plate and standing feet. Job done then and will move to some proper audio work!
Testing the circuit today, I measured 29 46 valves. Ended up discarding two which measured low and then when tested with the tracer found that curves weren’t good at all. Probably electrode misalignment as they weren’t just with low transconductance. Will upload some examples as it’s very interesting to see the difference
Listening to the 45 Single Ended (SE) Amplifier
A perfect and warm sound
Hard to describe in words what I felt when I played first time “Goodbye Pork Pie Hat” from Charles Mingus. Perhaps it was the due to the fact that I play saxophone, but inevitably for me this song is one of the best ones to test the response of any amplifier. Sax duets, solos, a great bass line and varied moods along the way can take the amplifier to their best of their abilities. Being a jazz fan, couldn’t help myself when listening this amplifier for the first time. I used to play an EL34 push-pull, and liked its sound and power – specially for rock. But when it comes to the first watt, this amplifier is breathless. Pure and a warm tone. Playing this song made me understand all the fuzz about single ended amps. But, far from opening the debate about that, I’m sure that a 45/46 in push-pull has its own merits and would probably will one of those amps I’d like to build in the future.
Having a FE167E full-range driver that have a relatively high efficiency (94dB/W), the 45 SE doesn’t sound low. It has its own personality. Brilliant for jazz, it may need a tad of power perhaps when playing some rock and classic stuff.
It took me some time to optimise the driver stage. Started with an SRPP, then a paralleled 6SL7 to an 6J5 loaded with a gyrator in mu-follower achieving less than 0.20% THD at 150 Vpp. A great driver in my opinion. Now need to replace the 6J5 for the lovely 7193.
It looks like a Frankenstein valve, but it’s a lovely thing to me. Many claim that it’s a superior valve compared to the 6SN7/6J5 or even CV1988.
Adding the 7193 will require opening my 45SE and not having music at home for some time so at the moment is not what I have in mind.
Perhaps when I get the 4-65A up and running? It will take some time for that…
Improved 46 triode-strapped DHT composite model
My initial attempt to get a reasonable SPICE model for a 46 triode-connected DHT has proven to be ok considering it was my first try. I got better accuracy with my second attempt using CX-301a. With time, I should learn the skills of Dmitry Nizh to master the great tool he has developed. For the ones who haven’t seen his website and great material Dmitry has produced around DHT, SPICE and other good stuff, I recommend you to read his article about composite models for DHT here.
Dmitry kindly produced a very accurate model for the 46 (and also shown clearly that I’m a still a rookie at this things ):
And here is the equivalent Spice model:
Using a simple circuit in LTspice we can test the model and trace the anode characteristic curves:
And the curves can be easily generated:
Note that grid voltage starts at 0V in -10V steps.