As part of my repairing of the curve tester, I had to do some changes to the transconductance (Gm) meter section. Currently I’m leveraging most of the curve tester to also measure Gm, μ and distortion (THD). Albeit the latter is rarely used as I prefer an external equivalent CCS circuit that is not inside the tester as the output signal comes out cleaner. The curve tester provides all sockets, HT power adaptor, meters and bias supply.

This is my latest circuit:

The additional protection to fuse (F1) is the diode D2 which can protect the LCD panel meter A1 in case of an unexpected anode short. P1 and R4 were chosen to allow a precise setting of the anode current at low levels and some protection to the CCS when P1 is set to zero. M1 is bolted to chassis and is carrying all the effort when providing current at lower anode voltages. M2 on the other extent can be a TO-92 type. R1 was added to allow a bleeding path to C2 when not measuring transconductance. The bias section is a simple adaptation of Merlin Blencowe’s “Power Supplies for Tube Amplifiers”, which I suggest you take a look at as Merlin covers very well the most common valve bias circuits

With this circuit I can measure very accurately transconductance at any desired point.  I highly recommend you Alan Douglas’ “Tube Testers and Classic Electronic Test Gear”, which has a lot of details around how classic valve testers work, challenges around Gm measurement and obviously some good ideas and suggestions for calibrating and measuring Gm correctly.

Obviously adding an amplifier to the Gm tester section could improve the accuracy of low transconductance valves. But that would be for another time!